New and Used Karl Storz Laparoscopic Instruments
Clear Choice Medical sells new and used Karl Storz laparoscopic instruments online and ships them to buyers across the United States. Current listings include Karl Storz graspers, scissors and dissectors, many of them CLICKLINE inserts sold on their own. Orders within the United States get free domestic shipping by standard ground, and every item carries a 30-day warranty against functional defects. Everything ships from our own inventory in Pinellas Park, Florida.
120 products
Where a title gives the Karl Storz catalog number, diameter and working length, use them to compare listings. Photos show the actual item that ships. If you want a close-up of a jaw or tip, ask and we will send it before you buy.
See every Karl Storz listing, or all Laparoscopy & Endoscopy instruments from every maker.
Clear Choice Medical is not affiliated with Karl Storz. Brand and model names identify the equipment being sold.
Which Karl Storz laparoscopic instruments are listed?
Many listings are Karl Storz CLICKLINE parts and instruments. Jaw types in the titles include atraumatic, fenestrated and double-action jaws. Reddick-Olsen dissectors and hook scissors are listed too.
Where a title gives a diameter, it is usually 5 mm. Some pieces are 3.5 mm or 10 mm. Working lengths of 36 cm and 43 cm are the most common.
Other listings include insulated monopolar instruments and bipolar handles. Trocars, cannulas and obturators are listed as well.
For laparoscopic graspers from every maker, see the Laparoscopic Graspers page.
How do CLICKLINE inserts, outer sheaths and handles fit together?
A CLICKLINE instrument is modular. The insert is the jaw and inner shaft. A complete instrument adds an outer sheath and a handle.
Karl Storz lists each part as its own device. Its FDA device records include CLICKLINE forceps inserts and CLICKLINE plastic and metal handles. They also include insulated metal outer sheaths in 36 cm and 43 cm lengths.
Titles call the sheath an outer sheath or an outer tube. Some listings sell one part alone. Others list a complete instrument, with a catalog number for each part.
Match an insert to an outer sheath of the same diameter and working length. Match the handle to the insert system and the handle style your team uses.
| Part | What it is | What the title usually gives | What to match |
|---|---|---|---|
| CLICKLINE insert | The jaw and inner shaft, listed on its own | Catalog number, jaw type, diameter and working length | The diameter and working length of your outer sheath |
| Outer sheath or outer tube | The tube the insert runs through, often insulated | Catalog number, diameter, working length and whether it is insulated | The diameter and working length of the insert |
| Handle | The grip that works the jaw, in plastic or metal | Catalog number, and sometimes rotating or monopolar | The insert system and the handle style your team uses |
| Complete instrument or set | An insert, sheath and handle listed together | A catalog number for each part | Each part number against your records |
| Trocar, cannula or obturator | The port the instruments pass through, and its tip | Diameter, tip shape and sometimes the valve | The diameter of the instruments you use |
Karl Storz device records checked in AccessGUDID on November 12, 2026. All sales are final. We do not accept returns. Every item ships non-sterile, and your facility processes it before clinical use.
How do I match a Karl Storz catalog number?
Start with the catalog number on the part you use now, or on your count sheet. Most titles on this page begin with the Karl Storz number.
Read the letters after the number as well. In these titles the letters change with the jaw. For example, 33310 G is an insert with 2 x 4 teeth, and 33310 FM is a claw insert with 2 x 3 teeth.
You can also search a number in AccessGUDID, the FDA's public device database. The Karl Storz record for 33132, for example, names it a CLICKLINE Metal Handle.
Not sure it is the right match? Call (727) 482-5016 before you order.
Common questions about Karl Storz Laparoscopy & Endoscopy instruments
What do the two sizes in a Karl Storz laparoscopic title mean?
The first size is the diameter, and the second is the working length. A title reading 5 mm x 36 cm describes an instrument 5 mm across with a 36 cm working length. The diameter sets the smallest trocar the instrument passes through. Karl Storz device records list CLICKLINE outer sheaths at 36 cm and 43 cm. Titles sometimes call the longer pieces bariatric. Match both figures to the outer sheath or trocar you already use.
Can I use a CLICKLINE insert with another maker's handle?
Do not assume it. CLICKLINE is a Karl Storz system, and Karl Storz lists its inserts, outer sheaths and handles as separate CLICKLINE devices. Match an insert to a CLICKLINE outer sheath of the same diameter and working length, and to a CLICKLINE handle. Then check each catalog number against Karl Storz documentation before you order. Clear Choice Medical is not affiliated with Karl Storz, and brand names identify equipment only.
What warranty comes with a Karl Storz instrument from Clear Choice Medical?
Every item carries Clear Choice Medical's 30-day warranty against functional defects. It is Clear Choice Medical's own warranty. Clear Choice Medical is an independent dealer and is not affiliated with Karl Storz. All sales are final. We do not accept returns. Every item ships non-sterile, and your facility processes it before clinical use. If you want a close-up of a jaw or tip, ask and we will send it before you buy.
Details checked .