Which used power tool systems does Clear Choice Medical list?
Clear Choice Medical has bought and sold new and used surgical instruments and medical equipment for more than 30 years. Its orthopedic power tools page lists these systems as inventory allows:
- Stryker battery systems: System 8 handpieces and batteries, plus System 7 and System 6 pieces
- Stryker console systems: CORE, TPS and RemB handpieces and attachments
- Medtronic Midas Rex: Legend high-speed drills and attachments
- ConMed Hall: PowerPro and Micro 100 handpieces, attachments and hoses
Clear Choice Medical is an independent dealer and is not affiliated with any manufacturer. Brand and model names identify equipment only.
How do battery, electric and pneumatic systems differ?
Surgical power tools run on battery, electric or pneumatic power. One maker groups them as small bone, large bone or specialty instruments.
Battery: Stryker System 8, System 7 and System 6
A battery handpiece carries its own power pack and charges on a separate charger. Stryker calls System 8 its battery powered heavy duty system.
Stryker groups the System 8 rotary drill and its sagittal, reciprocating and sternum saws as large bone tools. Stryker says System 7 and System 6 battery packs were made before System 8 packs.
Electric: Stryker CORE, TPS and RemB
Electric handpieces plug into a console by cord. CORE stands for Consolidated Operating Room Equipment, and TPS stands for Total Performance System.
The CORE 2 console runs small and large bone drills, saws and drivers through three handpiece ports. The RemB Universal Driver lists CORE, CORE 2 and TPS consoles.
Stryker's 2021 neurosurgical catalog lists the original CORE console and the Saber drill as obsolete, with servicing only until July 2021. Check service options for older models before you buy.
Pneumatic and high-speed: Midas Rex and Hall
Pneumatic handpieces run on compressed gas, such as air or nitrogen, fed by hose from a pressure regulator. Set the pressure from the IFU for the exact handpiece.
Midas Rex is Medtronic's high-speed drill line for cranial, spine, neurotology and ENT procedures. Its Legend platform has pneumatic motors and electric motors that run from Medtronic's Integrated Power Console.
Hall systems come in battery, electric and pneumatic versions. Hall listings may name Zimmer, Linvatec or ConMed. Linvatec was a Zimmer division until CONMED bought it at the end of 1997.
Stryker, Midas Rex and Hall systems compared
Check the IFU for your exact model before you buy.
| System | Power | Uses named by the maker or FDA | What fits, per the maker's documents |
|---|---|---|---|
| Stryker System 8 | Battery: 8212 small or 8215 large | Large bone orthopedic and cardiothoracic | 8203, 7203 and 6203 series rotary attachments. Charger 7110-120-000 or 6110-120-000 with module 6110-625-000 |
| Stryker System 7 and System 6 | Battery | Cutting and drilling bone | The 8215 battery lists System 7 handpieces. It does not list System 6 |
| Stryker CORE and CORE 2 | Electric console | Dental, ENT and neuro, plus spine and endoscopic | The RemB Universal Driver and Micro Drill, plus named TPS handpieces |
| Stryker TPS | Electric console | Dental, ENT, neuro and endoscopic | The RemB Universal Driver on TPS software 4.0 or higher, and the RemB Micro Drill |
| Medtronic Midas Rex Legend and MR7 | Pneumatic on air or nitrogen. Legend also has electric motors | Neurosurgery including craniotomy and spine, plus ENT and orthopedic | Legend attachments fit electric and pneumatic Legend motors and the MR7 |
| Medtronic Midas Rex MR8 | Electric and pneumatic | Cranial and spine | MR8 attachments and dissecting tools |
| ConMed Hall PowerPro | Battery, electric or pneumatic | Large and small bone surgery | Pneumatic handpiece attachments also used with PowerPro electric and battery systems |
Which handpieces, batteries, chargers and attachments fit together?
Each handpiece IFU lists the accessories meant for it. Check every part against that list, and do not assume a part from another maker or system family fits.
The System 8 rotary handpiece (8205) IFU lists 8203, 7203 and 6203 series attachments. The 8215 large battery IFU lists System 8 and System 7 handpieces, plus named cordless drivers and SABO saws. System 6 handpieces are not on it.
That battery charges on the Universal Battery Charger (7110-120-000) or the System 6 Battery Charger (6110-120-000). Either one needs the System 6 Charger Module (6110-625-000), so match the module number before you buy a charger.
For corded Stryker handpieces, match the console model and software version. The RemB Universal Driver lists TPS software 4.0 or higher and CORE software 5.7 or higher.
The table shows where Medtronic and Linvatec document shared attachments. If the IFU does not list a part, call us before you order.
What should you check before buying a used power tool?
- Read the catalog number on each handpiece, battery, charger module and attachment in the photos.
- Compare each number with the For Use With list in the handpiece IFU.
- For a corded handpiece, note your console model and software version.
- For a pneumatic handpiece, check the hose and the operating pressure in the IFU.
- Count the batteries and attachments in the photos, and see whether a charger or case is included.
Battery health
Stryker recommends using System 8 packs charged within the last 30 days. After charging, its Universal Battery Charger shows five to eight state-of-health bars, and more bars mean a better ability to store energy.
A REPLACE message means the pack failed the charger's state-of-health check. Some listings give each pack's charge cycle count, which this charger can display. Plan to charge each battery on your own charger when it arrives.
Cleaning and processing
Everything ships non-sterile, and your facility processes each item before clinical use. Follow the processing instructions for the exact model, because the rules differ.
Stryker lets System 8 handpieces be held under the cleaning agent during manual cleaning, but says not to soak any equipment. Non-sterile batteries in Stryker aseptic housings must not be immersed or put through a sterilization cycle.
Purchase terms
Every item carries a 30-day warranty against functional defects. All sales are final. We do not accept returns. International orders ship at a flat rate, and you can pay by card or PayPal.
Not sure a part matches your system? Call (727) 482-5016 or email info@ccmeddeals.com before you order.
Buyer FAQ
Where can I buy a used Stryker System 8 drill?
Clear Choice Medical sells used Stryker System 8 handpieces, including drills and saws, plus System 8 batteries. Standard ground shipping is free within the United States. Match the handpiece catalog number first, such as 8205 for the dual trigger rotary drill. Every item carries a 30-day warranty against functional defects. All sales are final. We do not accept returns.
Will a System 8 battery fit a System 6 or System 7 handpiece?
Stryker's IFU for the System 8 large battery (8215) lists System 8 and System 7 handpieces. System 6 handpieces are not on that list. The 8205 handpiece IFU does list System 6 battery packs among its accessories. So check both the battery IFU and the handpiece IFU before you order.
Can Stryker, Midas Rex and Hall attachments be swapped between makers?
Do not assume so. Each maker lists the attachments meant for its own handpieces. Medtronic says Legend attachments fit its electric and pneumatic Legend motors. Linvatec says its PowerPro pneumatic handpieces use attachments that are also used with its electric and battery systems. If a part is not on your handpiece's list, call (727) 482-5016 before you order.
Is a used power tool ready for surgery when it arrives?
No. Everything ships non-sterile, and your facility must process each item before clinical use. Use the processing instructions for the exact model, because cleaning limits differ by maker. Stryker says non-sterile batteries used in aseptic housings must not be immersed.